Figure (
2)
Caution:
For safet
y, the gap between the hob and any cupboard above it should be at least 750 mm.
3. Fix the h
ob to the worktop using the four brackets on the base of the hob. The position of
the brackets can be adjusted according to the thickness of the top.
Caution:
(1) The induction hob must be installed by a properly qualified person.
Never try to install the appliance yourself.
(2) The induction hob must not be installed above refrigerator
s, freezers, dishwashers or
tumble dr
yers.
(3) The induction hob should be installed so that optimum radiation of heat is possible.
(4) The wall and the area above the hob should be able to withstand heat.
(5) To avoid any damage, the sandwich layer and adhesive should be heat-resistant.
Connection to power supply
The socket should be connected in complian
ce with the relevant standard, to an
omnipolar circuit breaker. 30 A
MP minimum supply
The method of connection is
shown in Figure 3.
- 4 -
Air intake
Air exit
mini 5 cm
mini 5 mm
mini 2 cm
mini 750 mm